Reshaping your communication power.
Product Specs: Power Components
Power Panel
Max output 10A/channel. Max 30A total indication for each DC out.
Designed to meet MIL-STD-810F & MIL-STD-461E
Temp ranges: Operating: -20 - +55 Celsius
Storage: -40 - +70 Celsius
Connections:
1 X DC in, 10-32V DC, Mil connector
6 X DC out, same as input voltage
Custom connectors available
UPS
On/Off button. Suiitable for 12V and 24V systems. Visual and sound warning/indicators
(UPS mode, battery degrading etc). Lithium-ion Battery.
Designed to meet MIL-STD-810F & MIL-STD-461E
Temp ranges: Operating: -30 - +55 Celsius
Storage: -50 - +60 Celsius
10-19V DC The UPS is automatically set to suit a 12V system
DC output in normal mode: Pass-through(10-19V DC)
DC output on UPS mode: 13,2V (10-14.5V) DC, Max 10A
19-32V DC The UPS is automatically set to suit a 24V system
DC output in normal mode: Pass-through(>19-32V DC)
DC output in UPS mode: 26.4V DC, Max 10A
Connections:
1 X DC in 10-32V DC, Mil connector
1 X DC out Mil connector
Auto-detection
1x RS232 port for status communication and secure automatic shut down
Battery:
2 x 4 cells Litium-Ion, each cell 3.3V ( nominal)
In 12v mode they are connected in parallel, giving a total of 13.2V DC (10-14.5V)
In 24v Mode they are serially connected, giving a total of 26.4V DC (>19-28.8V)
Battery Life at max load:
Up to 10 min backup on 24V 10A (240W)
Up to 20 min backup on 12V 10A (120W)

For more specific information, or help specifying your system, click here.
|